Century CC1212 Panduan Pemilik - Halaman 10
Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Pengisi Daya Baterai Century CC1212. Century CC1212 13 halaman. 9-stage battery charger and maintainer
ONLINE RESOURCES
Visit http://www.centurybatteries.com.au/battery-charging or
http://www.centurybatteries.co.nz/battery-charging for more information on battery
charging and for advice on which Battery Type and Charge Rate settings to select when
using Century's CC1212 battery charger and maintainer.
TROUBLE SHOOTING
Problem
Charger does not
work?
Charger has no DC
output?
No charging current? Fault Red LED
The full / float light
won't come on.
9 • Owner's manual - Model. CC1212
Indication
Possible Causes
No Indicator
- No AC power
lights on
Fault Red LED
- Output is short
is ON
circuited
- Reverse polarity
protection
- Loose / bad
connection to the
battery
- Battery is severely
is Flashing
sulphated
- Battery has a
damaged cell
- Overheat
protection mode
Fault Red LED
- Battery Ah
is Flashing
capacity too large
for the battery
or
charger and it has
time out
Full Green LED
- Battery is
is Flashing
defective
- Battery is severely
sulphated
Suggested Solution
- Check AC connections and
make sure the AC Power Point is
switched ON.
- Try a different AC Power Point
which you know is working.
- Check DC connection between
charger and battery and make
sure they are not short circuited.
(Touching each other)
- Check that the crocodile clips
have not fallen off or come loose.
- Check that the crocodile clips/
ring terminals are connected to
the correct polarity.
Note: The charger output is only
present when connected to a
battery.
- Check the battery condition,
age etc.
- Battery may need replacement.
- Move battery & charger to a
cooler environment.
- Check the charger
specifications match the battery
capacity. Eg. make sure battery
capacity is not too big for the
charger.
- Battery may need replacement.
- Charge rate selected might be
too low for the battery. Switch
charger off and on and try again
or try a higher charge rate setting
providing it doesn't exceed the
maximum charge limit for your
battery.