3.1.2 On-air subscription of the CT-DECT Multi (PP) to the CT-DECT Case (8) (FP)

NOTES
The on-air subscription is not part of the normal commissioning and operating procedure
for the system. It must be performed again only in the case a CT-DECT Multi (PP) that isn't
subscribed to the CT-DECT Case (8) has to be used in conjunction with the CT-DECT Case
(8).
A CT-DECT Multi (PP) can be subscribed to only one CT-DECT Case (8), never to two or
more CT-DECT Case (8) units simultaneously.
NOTES
Two ore more CT-DECT Multi (PP) can never be simultaneously subscribed to the CT-DECT
Case (8), they must always be subscribed one after the other.
With two ore more CT-DECT Multi (PP) it is recommendable to subscribe all devices one after
the other to the CT-DECT Case (8), because a device can be deleted (see 3.1.2.1 »Principle of
subscription«).
Comply with the instruction step sequence.
After subscription all new subscribed devices have to be switched off again.
The on-air subscription procedure is performed on the CT-DECT Multi (PP) and the CT-DECT Case (8)
manually by means of operating elements. The CT-DECT Case (8) is the unit to which the maximum
eight (8) CT-DECT devices (PP) of a system need to be subscribed to.
3.1.2.1
Principle of subscription
Four CT-DECT Multi (PP) can be assigned to each transceiver module in the CT-DECT Case (8). The
four CT-DECT Multi (PP) assigned to a transceiver module should always be subscribed in groups, but
of course individually one by one.
Should a fifth CT-DECT Multi (PP) be subscribed to one and the same transceiver module, then the
CT-DECT Multi (PP) subscribed first would be deleted from the transceiver module's memory (see ex-
ample in figure 9).
A CT-DECT Multi (PP) which has been deleted from the CT-DECT Case (8) memory cannot communi-
cate anymore with the DECT system and needs to be re-subscribed to the base unit following the sub-
scription instructions.
Fig. 5 Principle of subscription (example)
12