IKEA IHI8304WS0 Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan - Halaman 4

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan Dan Panduan Penggunaan & Perawatan untuk Kap Ventilasi IKEA IHI8304WS0. IKEA IHI8304WS0 28 halaman. 30" (76.2 cm) island canopy range hood

INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
Level
Drill with 11¼"(3.0 cm), 3/8"(9.5 mm), %4" (2.75 mm) and
V8" (3.0 mm) drill bits
Pilot hole drill bits (determined by chimney support
attachment
method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof
caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Parts needed
Home power supply cable
2 - 1/2"(12.7 mm) UL listed or CSA approved strain reliefs
3 UL listed wire connectors
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented
(recirculating)
installations,
you will also
need:
Charcoal Filter Kit Part Number 4396848 for non-vented
(recirculating)
installations only. See "Assistance
or Service"
section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs
installed
Deflector for non-vented
(recirculating) installations
Filter-
installed in hood canopy
37- 3.5 x 9.5 mm screws
6-6x70mmscrews
6- 10 x 70 mm drywall anchors
12-M4x6mmscrews
12- captive nuts
Mounting template
4 vent covers with 4 trim pieces
Torx ®t adapter T10
Torx ®adapter T20
t®TORX
is a registered trademark
of Acument
Intellectual
Properties, LLC.
IMPORTANT." Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility
to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating
plate is located behind the filter on the rear wall of the range
hood.
Range hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions
provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements"
section.
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 80 Ibs (36.3 kg).
The range hood is factory set for venting through the roof or wall.
For non-vented (recirculating)
installations see "Non-vented
(recirculating) Installations"
in "Complete Chimney support
Installation" section. Charcoal Filter Kit Part Number 4396850 is
available from your dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured
Home Construction
Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction
and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured
Home
Installation 1982 (Manufactured
Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
14"
(35.5cm)
"31V2....
31_/2 ''
(80.0cm) (80.0cm)
rain.
rain.
"46_/2....
51%6"
(118.0 cm)
(131.0 cm)
max.
max.
0
*Vented installations only
**Non-vented
(recirculating)