INSTALLATION
The fixing bracket
3
frame so that the roller tube
height not less than 1,8m.
[FOR XQ50] Place the motor square pin
the cap at the opposite end of the tube on the fixing plate.
4
WARNING: Never hit on the head of the motor (D) when you
insert it into the tube.
NOTES
• For the XQ50, with torque up to 15Nm, the minimum tube diameter
is 50x1,5mm; for motors with higher torques, the minimum tube
diameter is 60x1,5mm.
• For the XQ60, the minimum tube diameter is 63x1,5mm.
WARNING:
• The screws used to fix the last slat on the tube may be too long
and reach the tubular part of the motor. Use appropriate screws or
fixing clips.
• Motor moving parts installed under 2,5m from the ground must be
protected.
• A wrong motor installation can damage persons or objects.
must be fixed inside the box or on the awning
9 0 °
F
is perfectly horizontal and at a
on the bracket
2/2
and
D
C