Garanterm Ravi HM 28 Instalasi dan Panduan Pengguna - Halaman 16
Jelajahi secara online atau unduh pdf Instalasi dan Panduan Pengguna untuk Ketel uap Garanterm Ravi HM 28. Garanterm Ravi HM 28 20 halaman. Conventional combi boiler
Garanterm Ravi Conventional Combi Boiler Installation and User's Manual
Figure 5
F
A
B
A
Central Heating Flow (3/4")
Sanitary Hotter Flow (1/2")
B
C
Gas Inlet
10
DIMENSIONS OF THE BOILER
Dimensions of the boiler are given in Figure 6.
Figure 6
Front
200
399
11
FLUE CONNECTION
When connecting the flue, the flue gas accessories
supplied by the manufactured must be used. When
selecting the location of the boiler the position of
flue gas connection and flue terminal should be
considered. For flue connection the requirements
set forth by the local authorities and gas distributing
company must be observed.
Flue connection must not be made to:
a. Building stairwells,
b. Building aisles,
c. Light-wells,
16
C
D
E
D
Sanitary Cold Water Inlet (1/2")
Central Heating Return (3/4")
E
F
Filling Tap
Side
180
335
d. On the chimney walls
e. Balconies
f. Elevator shafts.
The followings must be observed when making flue
connection:
a. Flue terminal vertical distance to eaves and roof
coverings should be minimum 1,5 m from the top
and should also extend further from such eaves
and roof coverings.
b. Minimum vertical distance above the ground
should be 0,3 m and in places where there is an
impact risk the flue terminal must be covered
with a wire net.
c. When the flue terminal is extended off the wall it
must extend minimum 50 mm outside the wall.
d. Horizontally connected flue connections must be
installed with 1% downward slope.
e. Where the appliance is installed to penthouses
flue terminal should be minimum 40 cm above
the roof. In such cases the roof must be insulated
with non-combustible material.
f. Maximum length of the flue connection is 4 m.
Maximum length is shortened by 1 meter for
each additional 90° elbow and 0,5 meter for each
additional 45° elbow.
g. Roof tightness must be fully ensured with vertical
flue applications. In case where tightness cannot
be ensured any failure or damage which may
arise is out of warranty claim.
Figure 7
L = max. 4 m
In the use of additional elbows
90°
1 m
45°
0,5 m
total equivalent length decreases.
L = max. 4 m
Total
equivalent = 5 m