E-T-A ESX10-TA-DC 24 V Buku Petunjuk - Halaman 4
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Pemutus sirkuit E-T-A ESX10-TA-DC 24 V. E-T-A ESX10-TA-DC 24 V 8 halaman. Electronic circuit protector
Connection diagrams and application examples ESX10-T
Connection diagrams and application examples ESX10-T...
Signal contacts are shown in OFF or fault condition.
ESX10-TA-100
+ line entry
1
LINE+
+24V
power
ESX10-TA-100
supply
DC 24 V
2 LOAD+
0V
3 0V
- line entry
+
-
Load
ESX10-TB-101
group signalling (series connection)
+ line entry for the SI
+ line entry
1
LINE+
14
13
13
+24V
power
supply
DC 24 V
ESX10-TB-101
0V
2 LOAD+
3 0V
- line entry
+
-
Load
ESX10-TB-102
Single signalling with common line entry
+ line entry for the SI
+ line entry
1
LINE+
12 11
+24V
11
power
supply
DC 24 V
ESX10-TB-102
ESX10-TB-102
0V
2 LOAD+
3 0V
- line entry
+
-
+
Load
Load
screw
terminals
terminals for
busbars
1
1
LINE+
LINE+
ESX10-TA-100
ESX10-TA-100
2 LOAD+
2 LOAD+
3 0V
3 0V
+
-
+
-
Load
Load
LINE + busbar
(X 222 611 02 or X 222 611 xx)
1
1
LINE+
LINE+
14
14
13
ESX10-TB-101
ESX10-TB-101
2 LOAD+
2 LOAD+
3 0V
3 0V
+
-
+
-
0 V busbar
(X 222 611 02
Load
Load
or X 222 611 xx)
single signalling
per way
by means of
an LED
LINE+ busbar
(X 222 611 02
or X 222 611 xx)
1
1
LINE+
LINE+
signal busbar
12 11
12
(X 222 005 03)
for common
line entry
ESX10-TB-102
2 LOAD+
2 LOAD+
3 0V
3 0V
0 V busbar
(X 222 611 02
-
+
-
or X 222 611 xx)
Load
ESX10-TB-124
Single signalling with common reset
LINE+ busbar
(X 222 611 02
or X 222 611 xx)
Reset
button
+ line entry
1
LINE+
+24V
22
RE SF
power
supply
DC 24 V
ESX10-TB-124
0V
- line entry
+
Load
0 V busbar
(X 222 611 02
or X 222 611 xx)
Application examples: line entry DC 24 V with
protection of signal circuit and direct connection of loads
Auxiliary contacts are shown on the OFF of fault condition
ESX10-TB-101
Group signalisation (series connection)
Type ESX10-TA-100-DC24V-0.5A can be used as a
supply module including protection of auxiliary circuit
Optional: Passive supply module AD-TX-EM01 (without protection)
group signalling
by means of an
signal lamp
+ line entry
jumpers
+ 24 V
(X 222 005 13)
are staggered
power
supply
0,5 A
DC 24 V
ESX10-TA-100
0 V
- line entry
ESX10-TB-102
Single signalisation with common line entry
Type ESX10-TA-100-DC24V-0.5A can be used as
a supply module
including protection of auxiliary circuit
Optional: Passive supply module AD-TX-EM01 (without protection)
+ line entry for SI
+ line entry
1
LINE+
+ 24 V
power
supply
0,5 A
DC 24 V
ESX10-TA-100
2 LOAD+
0 V
3 0V
- line entry
- 4 -
1
1
LINE+
LINE+
23 22
23 22
23
RE SF
RE SF
ESX10-TB-124
ESX10-TB-124
2 LOAD+
2 LOAD+
2 LOAD+
3 0V
3 0V
3 0V
-
+
-
+
-
Load
Load
+ line entry for SI
1
1
1
LINE+
LINE+
LINE+
13
14
13
14
ESX10-TB-101 ESX10-TB-101 ESX10-TB-101
2 LOAD +
2 LOAD +
2 LOAD +
3 0V
3 0V
3 0V
+
-
+
-
Load
Load
1
1
LINE+
LINE+
11
12
11
12
11
ESX10-TB-102 ESX10-TB-102 ESX10-TB-102
2 LOAD+
2 LOAD+
3 0V
3 0V
+
-
+
-
Load
Load
single signalling per
way by means of
an LED
LINE+ busbar
(X 222 611 02
or X 222 611 xx)
signal busbar
(X 222 005 03)
for common reset
0 V busbar
(X 222 611 02
or X 222 611 xx)
LINE+ busbar
(X 222 611 02
or X 222 611 xx)
group
signalisation
by means of a
signal lamp
1
LINE+
13
14
jumpers
(X 222 005 13)
2 LOAD+
are staggered
3 0V
+
-
0 V busbar
Load
(X 222 611 02
or X 222 611 xx)
single signalisation per way
by means of an LED
LINE+ busbar
(X 222 611 02
or X 222 611 xx)
1
LINE+
12
signal busbar
(X 222 005 03)
2 LOAD+
for common
3 0V
line entry
0 V busbar
+
-
(X 222 611 02
Load