Error codes

Error
Scenario
No cookware or
EO
non-usable cookware
E1
Low-voltage
E2
High-voltage
Top plate sensor overheat or
E3
short circuit
Top plate sensor open circuit or
without connection
1) The sensor has been damaged.
Could be damaged during
E4
the shipping
2) The connection of sensor and
PCB is bad because the fasteners
are loose
IGBT sensor overheat or short circuit
E5
or fan without connection
10
Check Point
Remedy
Please make sure you are using the correct and
high-quality, induction-ready cookware. Steel, cast
iron, enameled iron, or stainless steel with flat-bottom
pans / pots with diameter from 5" to 10". Unit will not
switch ON to heat. Unit will switch to Standby mode
after 1 minute.
Error code E1 occurs when the voltage is lower than
100V. Please ensure voltage is higher than 100V.
Error code E2 occurs when the voltage is higher than
280V. Please ensure Voltage is lower than 280V.
1) Error code E3 occurs when the temperature of
sensor overheats and boil dry protection is activated
(which can be caused when the temperature of
cookware is over 450F) during cooking. The
induction cooker needs to be turned off, unplugged,
and allowed to cool. Then you can turn it back on.
2) If E3 occurs after following step above, then
sensor has failed. Please contact customer service.
If you can see loose wires, then contact
customer service.
1) If error code E5 occurs and the cooling fan is
still functioning, please contact customer service.
2) If error code E5 occurs and the cooling fan has
stopped functioning or is not running well, check
to see if anything is lodged in or jamming the
cooling fan.