Empire OP36FB2MF-3 Petunjuk Pemasangan dan Panduan Pemilik - Halaman 5

Jelajahi secara online atau unduh pdf Petunjuk Pemasangan dan Panduan Pemilik untuk Perapian Dalam Ruangan Empire OP36FB2MF-3. Empire OP36FB2MF-3 16 halaman.

Empire OP36FB2MF-3 Petunjuk Pemasangan dan Panduan Pemilik

HOMEOWNER REFERENCE INFORMATION

We recommend that you record the following information about your firebox.
Model Number: _____________________________
Serial Number: _____________________________
Dealer Name: ______________________________
Notes: ______________________________________________________________________________
Instructions to Installer
1. Leave instruction manual with owner after installation.
2. Show home owner Product Registration Card supplied with
firebox.
3. Fill in the Homeowner Reference Information above.
4. Show owner how to start and operate outdoor burner (not
provided).
Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation of
an outdoor firebox.
This application is only for use with the type of gas indicated on
the burner rating plate. Burner sold separately.
Any change to this FIREBOX can be dangerous.
Improper installation or use of the firebox can cause serious
injury or death from fire, burns, explosion or carbon monoxide
poisoning.
This firebox is design certified in accordance with American
National Standard Z21.91 for outdoor use with Z21.97 burners.
Note: This firebox has been tested and approved up to
50,000 BTU's. DO NOT USE WITH BURNERS OVER 50,000
BTU's.
Important
All correspondence should refer to complete Model Number, and
Serial Number. Refer to the Homeowner Reference Information
above.
33857-4-0117
INTRODUCTION
WARNING
Date purchased: ________________________
Location of firebox: ______________________
Dealer Phone: _________________________
Moisture Resistance
This outdoor firebox will shed moderate amounts of water, but is
not waterproof. Water and condensing water vapor may enter the
chase under certain conditions.
The firebox will not perform as an exterior wall. Moisture
penetration must be considered for construction that places the
firebox in structure walls or on moisture sensitive surfaces.
When installed next to exterior walls: Empire Comfort Systems
recommends the firebox chase be constructed outside the
structure's weather envelope. Where the platform meets the wall,
use a flashing detail similar to that required for attached decks.
Chase platforms, including hearths should slope away from the
structure at 1/4 inch per foot. The firebox can be shimmed level.
When installed on surfaces where water may collect or cause
damage: Empire Comfort Systems recommends a slope of
1/8 inch to 1/4 inch per foot towards the drain port suggested.
The firebox can be shimmed level.
Hearths should slope away from the front of the firebox and
chase at 1/8 inch to 1/4 inch per foot. Metal safety strips must
be on top of any combustible hearth materials used for moisture
management.
When purchasing a firebox we recommend you also buy a
weather cover or glass door accessory to protect the firebox from
moisture. Never install the firebox where moisture cannot drain
easily.
Screened Porch Installation
The firebox may be installed safely and is design certified by UL
to be installed in a screen porch with the following guidelines.
Minimum Porch Area
Minimum Ceiling Height
See Pages 10 - 11, Planning Installation.
96 sq ft
84 inch
Page 5