Avastor XD5 Panduan Pengguna - Halaman 14
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Kandang Avastor XD5. Avastor XD5 19 halaman. Desktop raid
RAID Rebuild with No Spare Drive
Should a drive fail or become degraded, the XD5 alarm will sound
beep and the LED of the faulty drive will flash red.
Power the XD5 off and remove the faulty drive.
Install a known good drive into the same drive slot from which the
faulty drive was removed.
NOTE: The new drive must be equal to or larger than the largest
drive in the array. The new drive does not need to be formatted.
The new drive should be erased; any data on the new drive will be
lost when rebuild begins.
The RAID array will start rebuilding as soon as the XD5 is powered
on.
The rebuild is complete when the new drive stops flashing red and
turns blue.
LED INDICATORS
Disk Not Detected
Disk Detected/Power On
Data Access
Disk Failure
Disk Rebuild
Indicators
Source Disk
Rebuild Disk
14
Color
Off
Blue
Flashing Blue
Flashing Red
Flashing Blue
Flashing Red
VER 1.0