ENGLISH
Symptom
Variable-Speed
Incorrect dip switch setting.
Controller LCD
Make sure pump dip switches 1 and 2 are both ON if the controller is the JEP-R and both are OFF if the
is not displaying
controller is a PDA, AquaLink RS, or AquaLink Z4. See "3.2.4.1 Install with AquaLink® controller"
information
or
Improper low-voltage wiring.
pump LEDs are
Check low-voltage wiring between pump and controller. Correct if necessary. See "3.2 Electrical Installation"
not illuminated.
Controller
Improper low-voltage wiring.
displays "Pump
Check low-voltage wiring between pump and controller. Correct if necessary. See "3.2 Electrical Installation"
not connected".
Improper pump address set.
Ensure pump dip switches 3 and 4 are set properly for the installation. Both should be OFF for use with
Variable-Speed Controller or set to the proper address when connected to an AquaLink RS, AquaLink PDA,
or an AquaLink Z4. See "3.2.4.1 Install with AquaLink® controller"
Fault message
Fault condition exists.
appears on
View fault message on controller and correct fault before proceeding. If unsure how to correct fault, contact
controller display.
Zodiac Technical Support at 800.822.7933.