Empire Comfort Systems Boulevard VFLB72FP90N-1 Panduan Pemilik Rumah - Halaman 11

Jelajahi secara online atau unduh pdf Panduan Pemilik Rumah untuk Perapian Dalam Ruangan Empire Comfort Systems Boulevard VFLB72FP90N-1. Empire Comfort Systems Boulevard VFLB72FP90N-1 12 halaman. Contemporary linear vent-free gas fireplace models

Empire Comfort Systems Boulevard VFLB72FP90N-1 Panduan Pemilik Rumah
Annual inspection and cleaning by the dealer or qualified service
technician is recommended to prevent malfunction.
TURN OFF FIREPLACE AND ALLOW TO COOL BEFORE
CLEANING.
Remove any optional decorative covers or decorative glass
material. Gloves are recommended.
PERIOdIC CLEANING - Refer to parts diagram for location of
items discussed below.
Do not use cleaning fluid to clean any part of fireplace.
Clean glass with ammonia-free cleaner. Ammonia will etch
or stain glass when heated. (We recommend gas fireplace
glass cleaner.)
Remove loose particles and dust from the burner, controls
and air shutter.
Inspect and clean burner air intake hole. Remove lint or
particles with brush. Failure to keep air intake hole clean will
result in sooting and poor combustion.
ANNUAL CLEANING/INSPECTION - Refer to parts diagram
for location of items discussed below.
Inspect and clean burner air intake hole. Remove lint or
particles with vacuum or brush. Failure to keep air intake
hole clean will result in sooting and poor combustion.
Inspect and clean all burner ports.
Inspect ODS pilot for operation and accumulation of lint at air
intake holes.
Verify flame pattern for proper operation.
Verify smooth and responsive ignition of main burner.
PILOT MAINTENANCE ANd CLEANING
Oxygen depletion Sensor Pilot
When the pilot has a large yellow tip flame, clean the Oxygen
Depletion Sensor as follows:
1.
Use canned air to blow through hole A. See Figure 22.
This will blow out foreign materials such as dust, lint and
spider webs.
B
INTERMITTENT PILOT
40390-0-0119

CLEANING ANd SERVICE

C
A
Figure 22
Never use needles, wires, or similar cylindrical objects to
clean the pilot to avoid damaging the calibrated ruby that
controls the gas flow.
2.
If intermittent pilot fireplace stops working, clean flame
sensor B Figure 22 with a damp cloth.
3.
If intermittent pilot ignitor does not spark, clean ignitor C
Figure 22 with a damp cloth.
CONTROL COMPARTMENT ANd BURNER MAINTENANCE
Keep the control compartment and burner area clean by
vacuuming or brushing area at least twice a year.
The fireplace can get very hot. Handle only when cool.
Always turn off gas to the pilot before cleaning. For relighting,
refer to lighting instructions located on the rating plate.
Never obstruct the flow of the combustion and ventilation air.
Keep the front of the fireplace clear of all obstacles.
BATTERY REPLACEMENT
An intermittent pilot may require more frequent battery changes.
To replace the batteries, follow these steps:
1.
Remove the cover from the electrical box on the wall.
2.
Replace the batteries inside the box.
3.
Replace the cover using four (4) #4 x 1/2 Phillips screws.
REMOTE
SWITCH
LED SWITCH
ON-OFF
LED SWITCH
COLOR MODE
WARNING
WARNING
COVER PLATE
Figure 23
Page 11