Gardena 1483 Panduan Petunjuk Pengoperasian - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Pompa Air Gardena 1483. Gardena 1483 18 halaman. Pressure tank unit electronic plus with dry-running safety
Juga untuk Gardena 1483: Panduan Petunjuk Pengoperasian (19 halaman)

Gardena 1483 Panduan Petunjuk Pengoperasian

Finding Faults

Important !
Unplug the pump.
Check the pump for possible
faults such as:
➔ Faulty or leaking back-flow
preventer at the end of
the suction hose
➔ Pump and suction hose
are not filled up with the
liquid to be pumped
➔ Backflow valve switch set
to START and was not set
to RUN once the pump
began pumping
Storing Your Pressure Tank Unit
Disposal
(in accordance with
RL 2002 / 96 / EC)
22
Yellow LED is lit
The "automatic self-priming mode" is no longer active and the
.
unit is no longer supplying water (e.g. no water in the container
or borse or the filter is dirty).
Note: The pump can be restarted at any time by pressing the
RESET button or by "re-plugging".
Green and yellow LEDs flashing quickly and alternately
(four times a second)
Warning: There is a leak in the pipe system.
.
The pump switches on and off because of a leak. If the pump
switches on and off more than 7 times within 2 minutes, the
control unit issues a warning via flashing LEDs and the motor
switches itself off.
Note: The pump can only be restarted by "re-plugging".
➔ Suction hose end is not
submerged into the liquid
➔ Outlet too low
➔ Suction hose or connec-
tions are not water-tight
➔ Suction filter clogged
➔ Air cannot escape on
delivery side since release
points are closed etc.
➔ Delivery pipe or consumer
are not water-tight
➔ The pump switches on and
off because of a leak. If the
pump switches on and off
more than 7 times within
Always remove the mains plugs before working on the
pump.
Protect your pump against frost.
➔ Set the switch to START and empty the
pump via the drain screw.
➔ Store you pump away from frost.
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
v Important : Make sure that the unit is disposed of via your
municipal recycling collection centre.
2 minutes, the control unit
issues a warning via flash-
ing LEDs and the motor
switches itself off.
Clear the fault. Plug in the
pump in order to start again
operation of the pump.
Shouldn't the pump start
priming, although you have
repeatedly pressed the
RESET button, please contact
one of our GARDENA Service
Centres (addresses you will
find on the rear side).