Problem
Charging is not possible.
Battery charge indicator
is continuously illuminated
[ Fig. O3 ]
Battery charge indicator
not illuminated [ Fig. O3 ]
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved
by GARDENA.

7. TECHNICAL DATA

Battery Pump
Max. delivery capacity
Max. pressure
Max. delivery head
Max. submersion depth
Max. media temperature
Min. water depth for operation
with foot / without foot (approx.)
Residual water level with foot /
without foot (approx.)
Weight (without Battery)
System Battery PBA 18V 2.5Ah W-B Unit
Battery voltage
Battery capacity
Number of cells (Li-Ion)
Appropriate POWER FOR ALL system Battery Chargers: AL 18..CV.
Battery Charger AL 1810 CV P4A
Mains voltage
Mains frequency
Rated power
Battery charging voltage
Max. battery charging current
Possible Cause
Battery temperature is outside the
(Lc)
permissible charging temperature
range.
Battery is defective.
(Lc)
is
Mains plug of the charger is not
(correctly) plugged in.
Socket outlet, mains cable or
charger is defective.
Unit
Value (Art. 14600)
l/h
2000
bar
2.0
m
20
m
1.8
°C
35
mm
50 / 25
mm
25 / 5
kg
1.8
Value (Art. 14903)
V (DC)
18
Ah
2.5
5
Unit
Value (Art. 14900)
V (AC)
220 – 240
Hz
50 – 60
W
26
V (DC)
18
mA
1000
Remedy
v Wait until the battery temperature is
between 0 °C – + 45 °C again.
v Replace the battery.
v Insert the mains plug into the mains
socket (completely).
v Check the mains voltage. Let the
charger be checked if necessary
by an authorised specialist dealer
or the GARDENA Service.
Value (Art. 14602)
2000
2.0
20
1.8
35
50 / 25
25 / 5
2.2
21