Warning! This machine produces an electro -
magnetical field during operation. This field
may under some circumstances interfere with
active or passive medical implants. To reduce
the risk of serious or fatal injury, we recom-
mend persons with medical implants to

3. Initial Operation

Connect hose via the GARDENA
Connection System:
1
ß
Pump installation:
5
6
12
19mm (3/4")- / 16mm (5/8") and 13mm (1/2") hoses can be
connected via the GARDENA Connection System.
Hose diameter
13mm (1/2")
16mm (5/8")
19mm (3/4")
The pump connection component
the manufacturer together with the check valve
v Connect hose via the relevant GARDENA Connection System.
Backflow preventer
The backflow preventer
after the pump has been turned off or taken out of operation.
With a parallel connection of more than one hose or connected
devices, the GARDENA 2- / 4-Way Valve (Art. 8193 / 8194) can
be used, which is screwed straight onto the pump connection
1
v
piece
.
The pump must always be submerged in the fountain or water
reservoir with the fastening rope
to be primed, the pump must be submerged to the minimum
3
submersion depth
So that the filter does not become dirty, the pump should be
fixed at least 30cm above the ground.
4
1. Attach the fastening rope
2. Submerge pump in the fountain or water reservoir via the
fastening rope
3. Secure fastening rope
4. With deep fountains or shafts (from approx. 5m), route the
connection cable
Thermal protection switch:
min.
In the event of an overload, the pump is switched off by the
ß
t
built-in thermal motor protection. After sufficient cooling of the
motor, the pump is operational again.
min.
30 cm
consult their physician and the medical implant
manu facturer before operating this machine.
Danger! Small parts could be swallowed dur-
ing assembly and there is a risk of suffocation
from the polybag. Keep infants away during
assembly.
Pump connection
GARDENA
Pump Connection Set
GARDENA Tap Connector
GARDENA Hose Connector
GARDENA
Pump Connection Set
1
is already pre-installed by
ß
:
v
ß
prevents the hose from running empty
v
3
provided. For the pump
ß
(see 8. Technical specifications).
t
3
to the handle
3
.
3
.
5
along the fastening rope
Art. 1750
Art. (2)902
Art. (2)916
Art. 1752
ß
.
v
4
.
3
with clips.