Gardena 6000/6 inox Premium 1736 Panduan Petunjuk Pengoperasian - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Pompa Air Gardena 6000/6 inox Premium 1736. Gardena 6000/6 inox Premium 1736 17 halaman. Garden pump
Juga untuk Gardena 6000/6 inox Premium 1736: Panduan Petunjuk Pengoperasian (10 halaman), Panduan Petunjuk Pengoperasian (12 halaman), Panduan Operator (14 halaman), Panduan Operator (10 halaman), Panduan Operator (10 halaman)

Gardena 6000/6 inox Premium 1736 Panduan Petunjuk Pengoperasian
Please note:

2. Safety Instructions

DANGER! Electric shock!
Risk of injury due to electric shock.
v Always unplug your Garden Pump before fil-
ling, after operation, when trouble-shooting
and before carrying out any maintenance work.
RISK OF INJURY!
Hot water – risk of scalding!
For pump 4000/5 only: If the pump is operated
for prolonged periods of time (> 5 min.) with
the delivery side closed, the water in the pump
may heat up so that there is a risk of scalding
yourself with hot water.
v The pump should not run against the closed
delivery side for more than 5 minutes.
If the water supply on the intake side of the
pump fails, the water in the pump can heat up
so that if water emerges, injuries could be
caused by the hot water.
v Disconnect the pump from the mains via
the main circuit breaker, let the water cool
and secure the suction-side water supply
before putting into operation again.
Location
Caution: Pursuant to DIN VDE 0100-702 and
0100-738, AS/NZS 3000 use of the pump nearby
swimming pools and garden ponds and other
similar places is only permissible if the pump is
operated via a residual-current device (FI switch)
with a residual current rating of ≤ 30 mA.
The pump must not be operated when there are
persons in the swimming pool or garden pond.
The pump must be located on solid, even ground,
protected from flooding. Take care that the pump
cannot fall into water. Position the pump at a safe
distance (min. 2 m) from the liquid to be pumped.
As an additional safety device an authorised safety
switch can be used.
14
The GARDENA Garden Pump is not suitable for continuous
operation (e.g. industrial applications, continuous circulat-
ing operation). Corrosive, easily combustible, aggressive or
explosive liquids (such as gasoline, petroleum or nitro
thinner), saltwater and food must not be pumped.
The temperature of the liquid must not exceed 35 °C.
v Please ask your electrician for his advice.
When connecting the pump to the water supply
system, the country-specific sanitary regulations
must be observed to prevent water not of drink-
ing water quality being drawn back in.
v Please consult a specialist for sanitary
installations.
Extension cables
Date indicated on the type plate must match
technical data of the mains supply.
Only use extension cables authorised in
accordance with HD 516.
v Consult your qualified electrician.
v Don't use the power cable for carrying the
pump or for plugging off.
In Austria
In Austria, the electrical connections must be
made according to ÖVE-EM 42, T2 (2000) /
1979 § 22 based on § 2022. Pursuant to this
regulation it's imperative to operate pumps for
swimming pools and garden ponds exclusively
via an isolating transformer.
v Please ask your electrician.
In Switzerland
In Switzerland mobile appliances which are
used outdoors, must be connected via a residual-
current device.
Visual check
v Before operating the pump, first make a visual
cheek, if there is any damage of the pump
(esp. regarding power cable and plug).
A damaged pump must not be used.
v In case of damage, please have the pump
checked by our GARDENA Service Centre or
by an authorised electrician.
v A damaged connection cable may only
be exchanged by GARDENA Service or an
authorised electrician.