7. Cleaning

The filter should be checked regularly and cleaned when
Clean filter :
necessary.
L
1. Unscrew sleeve nut
from the tap thread (do not use pliers).
2. Remove filter from sleeve nut
3. Screw sleeve nut
thread of the tap by hand (do not use pliers).

8. Trouble-Shooting

Fault
Possible Cause
No display appears
Battery inserted incorrectly.
Flat battery.
22
L
of the Water Computer by hand
L
and clean.
L
of the Water Computer back on to the
Remedy
v Check polarity markings
match (+ / –).
v Insert new (alkaline) battery.
v Check function by operating
manually (man. On / Off).
Fault
Possible Cause
No display appears
Temperature on the display
is higher than 60 °C.
Programs cannot be
The current time and the day
entered
of the week were not entered
completely.
Manual opening via the
Low battery power, Batt.
man. On / Off-key is not
indicator flashes
possible
Manual watering period is set
0 0 : : 0 0 0 0
to
.
Tap turned off.
Watering program is not
Watering program has not
being undertaken
been entered completely.
(no watering)
Programs deactivated
(Prog. Off).
Program entry / modification
during or just before the
start pulse.
Remedy
Display appears after
temperature has dropped.
v Check function by operating
manually. (man. On / Off).
v Enter time and day of week
(see 5. Programming).
v Insert new (alkaline) battery
v Set manual watering period
to a figure greater than
0 0 : : 0 0 0 0
(see 5. Programming).
v Turn tap on.
v Read off watering program
and modify if necessary.
v Activate program
(% Run-Time).
v Make program entry /
modification outside the
programmed start times.
23