Safety warnings during installation:
•
Installation must be carried out in accordance with
regulations of household wiring. Use conductors 1,5mm²
•
Communications, antenna and other low voltage
connectors are not allowed in the same mounting box
•
Installation and maintenance must be
carried out by qualified person
•
Turn off the power before installation or maintenance
•
The device is not suitable for outdoor installation
•
Overload, electric shocks and short circuits can destroy the
device. Before and after installation mandatory check circuit
•
In order to ensure air flow only single additional module
may be installed in the same mounting box
•
Install away from heat sources
Installation manual:
1.
Install mounting frame onto the mounting box.
2.
Connect the device according to the following scheme (Fig. 1).
On P-L input can optionally be connect more buttons in
parallel (1), which manually activate device.
Withal, on the same inputs can be added one-way switch
(2) if it is desired to have the possibility of manual
switching of the circuit independently of device's set time.
If it is needed to expand the area of operation,
several units can be connected in
parallel to a joint consumer (Fig. 2).
Fig. 1
Fig. 3
optional
Fig. 2
3.
Adjust the sensitivity of the device by trimmer G (Fig. 3).
Firstly place the trimmer approximately in the middle position.
Sensitivity varies depending on the ambient temperature,
humidity, speed of movement and if it proves to
be inappropriate, may subsequently be turned up.
4.
Press the device into the mounting frame.
5.
Finish the installation by putting the cover
frame, and then turn on the power.
Handling and use:
1.
Figure 4 shows a front view of the device 1 - lens detection,
2 - external light sensor, 3 - adjusts the light level at which the
device is activated, 4 - sets working time, 5 - switch, 6 - LED
indication automatic mode.
2.
After power is on, it is necessary to adjust the brightness level
at which the device is activated and the working time (Fig. 5).
The device is equipped with protection for not turning on the
light on a daylight. With trimmer (3) set up in what daylight
should activate passage of people. At a desired level of
daylight turn on a switch (2), at Fig. 1 and adjust the trimmer
(3) until the device is deactivated.
Working time is set with a trimmer (4) in the range from 10
sec to 10 min. After this time, in automatic mode, the device
switches itself off, if no one activates the device by passing.
3.
The role of switch (5)
A switch has 3 positions: 0, middle and I (Fig. 5). In position 0
the device is always turned off, in the middle position the
device is in automatic mode (activates only by passing the
person), and the position I - device is always on. When the
device is in automatic mode, illuminates LED indication (6).
Fig. 4
Fig. 5
Warning for safety usage:
1.
Connected consumers must not exceed the permitted load
2.
Do not use for purposes that are not explicitly listed
3.
The device must be in circuit with a fuse. Overload or short
circuit can permanently damage the device.
4.
Do not clean with alcohol, oil or solvents.
Simply use a dry cloth.
6
4
+2°
0°
1,2m
110°
0
-30°
-6°
0
1
2
3
4
5m
6m
Fig. 6
Technical specifications:
•
Power supply 230V ~ 50Hz
•
Permissible load depending on the nature of the load:
- 8A for resistive load (incandescent lamps)
- 4A for halogen bulbs
- 2A for fluorescent lamps
- 2A for motors, fans and other inductive loads
•
Power consumption <1W
•
Galvanic isolated relay output 230V~
•
The area of operation max 5m width detection 110 ° (Fig. 6)
•
Time setting 10 sec - 10 min
•
Operating temperature -20 ° C - +50 ° C
•
Adjusting the sensitivity,
level of daylight in which to be reapplied
New Quality Dimension
SERBIA • 21432 GAJDOBRA • Železnička 10
TEL.: +381 21/762-674, 762-586 • FAX.: +381 21/762-779
e-mail: [email protected]
www.aling-conel.com
IR motion detector
For control 230V~ incandescent or halogen
lamps, toroidal, electronic and laminated core
transformers, fluorescent lamps and fans
Item. 72203