alkitronic CLD Panduan Pengoperasian dan Pemeliharaan - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Pemeliharaan untuk Peralatan alkitronic CLD. alkitronic CLD 12 halaman. Compact torque multiplier
Juga untuk alkitronic CLD: Panduan Pengoperasian dan Pemeliharaan (12 halaman)
Operating and maintenance manual
2.3
Torque adjustment
The torque depends on the upcoming air pressure
of the engine. The desired air pressure can be set
via the pressure regulator of the maintenance unit.
The torque setting for the alkitronic® torque multiplier must
be set either on the maintenance unit (appendix E) or on the
air supply in accordance with the enclosed characteristic
data sheet (see sample illustration on the right). For the CLS2
and RCL types, there are 2 gears available (Fig. 1), the fast
and the power gear. The torques (Nm) are listed on a table
and are readable on the upper side of the handle (Fig. 2) of
the alkitronic® multiplier. The torque specifications are to be
regarded as adjusting aids. Option: Machine-specific torque
values can be factory determined with our calibration system.
Special connections and larger pressure and / or volume
fluctuations in the supply network can lead to deviations.
alkitronic® CLS2 / RCL
Sample illustration characteristics datasheet
2.4
Fig. 1
I. Gear
II. Gear
Fig. 2
6
Operating notes
During the first hours of operation (start-up phase)
it is possible that there is a slight leakage of grease
on the housing shells. In this case, remove grease
to avoid slipping during operation or to avoid
contamination.
In the event of loss of performance or other identifi-
able damage, send the alkitronic® torque multiplier
to your nearest alkitronic® Partner in the original
packaging as soon as possible or directly to alki
TECHNIK GmbH.
Type alkitronic® CLS2 und alkitronic® RCL:
Change gear (1st gear / 2nd gear) only when the en-
gine is stopped to prevent damage to the multiplier.
alkitronic® torque multiplier are designed for an
ambient temperature of -10 ° C to + 40 ° C. Exceed-
ing or exceeding these temperatures can cause
damage to the multiplier.