Blink Codes

When the GSD 22 is installed, it switches on when the chartplotter is powered on. The two-color (green and red) LED on the GSD 22 indicates
the current operational status of the device.
Code
Green blinking, on for 1 second, off for 0.5 second (slow blink)
Red blinking, on for 1 second, off for 0.5 second (slow blink)
Solid Red (no blink)
Red blinking, on for 1/10 second, off for 1/10 second
(very fast blink)
S
pecifications
Physical
Size:
7 ⅝ in. L x 6 ⅛ in. W x 3 in. H
(19.3 cm x 15.5 cm x 7.6 cm)
Weight:
2.1 lbs. (953 g)
Case:
Fully gasketed, high-impact plastic and aluminum alloy, waterproof to IEC 529-IPX-7
Temp Range:
From 5°F to 158°F (from -15°C to 70°C)
Electrical
Source:
10-35 Vdc
Usage:
25 watts maximum
Fuse:
AGC/3AG - 3.0 A
Compass Safe Distance:
Sonar
Sounder Power: 500/1,000/2,000 watts (RMS) (Dependent on transducer type.)
4,000 /8,000/16,000 watts (peak to peak) (Dependent on transducer type.)
Frequency:
50/200 kHz
Depth:
5,000 ft. (1.524 km) maximum depth (Depth capacity is dependent on transducer type, water salinity, bottom type, and
other water conditions.)

Data Output

Source: Garmin Marine Network
5.9 in. (150 mm)
Status
GSD 22 is servicing one directly-wired connection and the chartplotter is
operating properly.
You should see sonar data on the chartplotter.
GSD 22 is powered on but is waiting to connect to a chartplotter. In this state,
the GSD 22 does not transmit any sonar signals or send any sonar information
to chartplotters. If a chartplotter is connected and this code persists, check the
wiring.
Software failure - Call Garmin Product Support. If the cause is a software error,
the chartplotter can show the error. Power must be cycled to clear the error.
System alarm. The chartplotter gives a message indicating the type of failure.
After the alarm condition is fixed, power must be cycled on the GSD 22 to clear
the alarm.
GSD 22 Installation Instructions