7
placing the dishwasher
Position the appliance in the desired location. The back should rest against the wall behind it, and the sides along the adjacent
cabinets or walls. The dishwasher is equipped with water supply and drain hoses that can be
positioned either to the right or the left sides to facilitate proper installation.
Once the appliance is positioned for levelling, the height of the dishwasher may be altered via
adjustment of the screwing level of the feet. In any case, the appliance should not be inclined more
than 2°.
ELECTRICAL CONNECTION
Ensure the voltage and frequency of the power corresponds to those on the rating label. Only insert the plug into an electrical socket
which is earthed properly. Use the required fuse 10 amp.
COLD WATER CONNECTION
Connect the cold water supply hose to a threaded 3/4 (inch) connector and make sure that it is fastened tightly
in place.
If the water pipes are new or have not been used for an extended period of time, let the water run to make sure
that the water is clear. This precaution is needed to avoid the risk of the water inlet to be blocked and damage
the appliance.
Attention: the dishwasher can not be connected to a warm water supply.
DRAIN HOSE CONNECTION
Insert the drain hose into a drain pipe with a minimum diameter of 40 mm, or let it run into the sink, making sure to avoid bending or
crimping it. The top of the hose must be less than 1000 mm.
NOTE: The top of the
hose must be less
than 1000 mm.
IS THE DISHWASHER READY FOR USE?
1. The dishwasher is level and fixed properly.
2. The inlet valve is open.
3. The fill hose connections are fully tightened and not leaking.
4. The appliance is plugged in.
5. The drain hose is properly placed.
6. All packing materials and printings should be taken out of the dishwasher.
40
English
please hang up the drain hose either way A or B
front
drain pipe
Counter