Permanent Connection
In the case of a permanent connection, it is necessary that you install a double pole switch
between the hob and the electricity supply (mains), with a minimum gap of 3 mm. between
the switch contacts and of a type suitable for the required load in compliance with the current
electric regulations.
The switch must not break the yellow and green earth cable at any point.
Ensure that the hob supply cord does not come into contact with surfaces with temperatures
higher than 50 deg. C.
Supply Cable Specifications
For Uk use only
Connection
via
• Cooker
Control
Circuit
For Europe use only
Min. size Cable/flex
2.5 mm
2

Wiring diagram

18
Min. size
Cable / flex
Cable/flex
type
6 mm
PVC/PVC
2
twin and
earth
Cable / flex type
H05 RR-F
Fuse
30 A
Fuse
30 A