Technical data
Type of gas
Adjusted to natural gas: G20-20 mbar
Category and pressures
UK: II
20 mbar - 28/37 mbar
2H3+
Max. nominal load Q na H
:
S
Medium sized burner =
1,9 kW x 1
Large sized burner =
2,7 kW x 1
Total=
4,6 kW
FSD
The unit features fully-secured gas
taps (thermo-fuse).
H
= Top calorific value
S
Q = Nominal load
ID. CE-048AU-0002
Ignition transformer= 50 HZ - 0,6 VA
Radio-noise reduction
This unit observes the current EEC-
directive on radio noise reduction.
This gas appliance is
-approved and
marked in accordance with the gas
appliance Directive (90/396/CEE), the
low voltage directive (73/23/CEE) and
the EMC directive (89/336/CEE incl.
the agreed directive changes.
Cable type 0,75 mm² HO5 V2V2-F
240 V
1N + PE
N
L1
The hob must be connected via an
external switch with a contact
gap of min. 3 mm (the main switch
may be used)
Wiring
HO5V2V2-F
Blue and brown: 51 mm +/- 3 mm
Yellow/Green: 61 mm +/- 3 mm
12
Important safety requirements
This hob must be installed in
accordance with the Gas Safety
(Installation and Use) Regulations
(Current Edition) and the IEE
Wiring Regulations (Current
Edition).
Detailed recommendations are
contained in the following British
Standards Codes Of Practice: B.S.
6172/ B.S. 5440, Par. 2 and B.S.
6891 Current Editions.
The hob should not be installed in a
bed sitting room with a volume of
less than 20 m³. If it is installed in a
room of volume less than 5 m³ an
air vent of effective area of 110 cm²
is required. If it is installed in a
room of volume between 5 m³ and
10 m³ an air vent of effective area of
50 cm² is required, while if the
volume exceeds 11 m³ no air vent is
required.
However, if the room has a door
which opens directly to the outside
no air vent is required even if the
volume is between 5 m³ and 11 m³.
If there are other fuel burning
appliances in the same room, B.S.
5440 Part 2 Current Edition, should
be consulted to determine the
requisite air vent requirements.
This hob must be installed by
qualified personnel to the
relevant British Standards.
Any gas installation must be
carried out by a CORGI
registered installer.
The maufacturer will not
accept liability, should the
above instructions or any of
the other safety instructions
incorporated in this book be
ignored
13