Fujitsu PRIMERGY RX200 S6 Panduan Suplemen Servis - Halaman 32

Jelajahi secara online atau unduh pdf Panduan Suplemen Servis untuk Server Fujitsu PRIMERGY RX200 S6. Fujitsu PRIMERGY RX200 S6 50 halaman.

Fujitsu PRIMERGY RX200 S6 Panduan Suplemen Servis
Replacement routines
4.4

Replacing the UFM

The connector for the UFM (USB Flash Module) is located near PCI slot #3 and
might be hidden by an installed modular RAID controller.
Removing the defective UFM
Ê Open the server as described in the
page
23.
Ê If necessary, remove the modular RAID controller (for a description, see the
Options Guide).
Figure 12: Position of the UFM on the system board
Ê Remove the nylon screw of the defective UFM (see circle).
Ê Disconnect and remove the defective UFM.
The UFM spacer remains on the system board.
32
section "Opening/closing the server" on
Service Supplement
RX200 S6