Solaris OS Issues and Workarounds for All Supported Releases (Continued)
TABLE 7
CR ID
Description
6537511
Bluetooth partner is hung during security tests
execution.
6660168
If a ubc.piowbeue-cpu error occurs on a
domain, the Solaris Fault Management
cpumem-diagnosis module might fail, causing
an interruption in FMA service.
If this happens, you will see the following
output in the console log:
SUNW-MSG-ID: FMD-8000-2K, TYPE:
Defect, VER: 1, SEVERITY: Minor
EVENT-TIME: Fri Apr 4 21:41:57 PDT
2008
PLATFORM: SUNW,SPARC-Enterprise,
CSN: 2020642002, HOSTNAME:
<hostname>
SOURCE: fmd-self-diagnosis, REV:
1.0
EVENT-ID: 6b2e15d7-aa65-6bcc-bcb1-
cb03a7dd77e3
DESC: A Solaris Fault Manager
component has experienced an error
that required the module to be
disabled. Refer to
http://sun.com/msg/FMD-8000-2K for
more information.
AUTO-RESPONSE: The module has been
disabled. Events destined for the
module will be saved for manual
diagnosis.
IMPACT: Automated diagnosis and
response for subsequent events
associated with this module will
not occur.
REC-ACTION: Use fmdump -v -u
<EVENT-ID> to locate the module.
Use fmadm reset <module> to reset
the module.
6668237
After DIMMs are replaced the corresponding
DIMM faults are not cleared on the domain.
Workaround
Restart application server.
If FMA service fails, issue the following
command on the domain to recover:
# svcadm clear fmd
Then restart cpumem-diagnosis:
# fmadm restart cpumem-diagnosis
This has been fixed in patch 143527-01.
[Workaround]
Use the following commands:
# fmadm repair fmri|uuid
# fmadm rotate
Information About Software