Fujitsu SPARC Enterprise M9000 Catatan Produk
Documentation Updates (Continued)
TABLE 2
Title
SPARC Enterprise
M8000/M9000 Servers
Service Manual
SPARC Enterprise
M8000/M9000 Servers
Service Manual
SPARC Enterprise
M8000/M9000 Servers
Service Manual
SPARC Enterprise
M8000/M9000 Servers
Service Manual
SPARC Enterprise
M8000/M9000 Servers
Service Manual
Page Number
4-3
4.2.1.2, "Disconnecting a PCI card"
The following caution will be added.
4-23
4.7, "Power-On and Power-Off Procedures for the Cabinet with
the Dual Power Feed Option and the M9000 Expansion Cabinet"
See
"Power-On/Off Procedures of the Server with Expansion
Cabinet" on page 14
10-1
CHAPTER 10, "Operator Panel Replacement"
11-1
CHAPTER 11, "XSCF Unit Replacement"
The following important message will be added.
Note – If you replace the XSCF unit and the operator
panel simultaneously, system will not operate normally.
Execute the showhardconf command or the
showstatus command to confirm that the component
replaced earlier is operating normally, before replacing
the subsequent FRU.
12-3
12.2, "Active Replacement" Step 2
The following sentence will be added at the end.
"READY LED (green) of HDD turns off."
12-5
12.2, "Active Replacement" Step 9
The following sentence will be added at the end.
"READY LED (green) of HDD turns on."
Update
Caution – In the PCI cassette part,
when removing cables such as LAN
cable, if your finger can't reach the latch
lock of the connector, press the latch
with a flathead screwdriver to remove
the cable. Forcing your finger into the
clearance can cause damage to the PCI
card.
for the changes.