Hardware Installation and Service Issues
Notes on the Use of 200V Power Supply
For the servers that have the plug with lock function, confirm that a 15A overcurrent
protection device is available outside the server. If one is not available, prepare an
external 15A overcurrent protection that can be achieved by means of no-fuse
breakers (NFBs) or fuses. The plug with lock function refers to plugs other than
grounding-type ones with two parallel blades, such as the NEMA L6-30, L6-20, L6-
15, and L5-15.
For details of the power cord type for your server, contact your authorized service
engineer.
General Functionality Issues
RAID Function
A hardware RAID function is provided as standard in SPARC Enterprise T2000
servers. However, with regard to data protection, reliability, and serviceability,
Fujitsu does not support this function.
Fujitsu recommends use of software RAID functions for internal disks as specified
below:
PRIMECLUSTER GDS
■
Solaris Volume Manager (included in Solaris OS)
■
False IO-Bridge Errors May Be Reported at Startup
(CR 6792174)
This bug can occasionally cause POST to report a false PCIE-to-PCIX bridge chip
error the first time a system starts up. If this occurs, the system will reset. When it
restarts, POST will behave correctly.
4
SPARC Enterprise T2000 Server Product Notes • September 2011