R
P
A
EPLACING THE
AD
SSEMBLY
A defective or improperly installed Pad Assembly can cause misspicks,
skew, or double fed documents. To replace the Pad Assembly perform
the following steps.
•
Remove all documents
from the ADF Paper
Chute. Open the ADF
by pulling the ADF
button up.
•
Remove the Pad
Assembly by pressing
Down on the pick arm
then pull out the pad
assembly to remove it.
•
Attach the new Pad
Assembly while
pressing down on the
pick arm so it is out of
the way. Be sure to
seat the pad
completely to avoid
jamming of paper
being fed.
Note:
After replacement of any consumable reset the counter for that
consumable by following the "Consumables Page Count" Section at
the front of these instructions to reset paper counts.
fi-4110EOX2/S
S
CAN
NAP
Open ADF
to Front
Pad Assy.
Pad Assy.
C
R
ONSUMABLE
EPLACEMENT AND
ADF button
Push down on
pick arm to
remove pad.
C
I
LEANING
NSTRUCTIONS
5