Juga untuk Fujitsu ETERNUS DX60: Setup Manual (4 halaman), Panduan Pengguna (35 halaman), Panduan Pengguna (42 halaman), Setup Manual (4 halaman), Menggunakan Produk Opsional (2 halaman), Panduan Konfigurasi (16 halaman), Menggunakan Produk Opsional (2 halaman), Pengenalan Produk (19 halaman), Isi Paket (4 halaman), Manual (4 halaman)

Fujitsu ETERNUS DX60 Panduan Konfigurasi
Chapter 7
Checking Connections
7.2
Setting Up the Server to Recognize the Logical Units
Check that all connected devices are listed in the ioscan output and "CLAIMED" is displayed in "S/W
State".
The following example shows the output of ioscan (LegacyView) when ETERNUS DX storage systems are
connected to a server.
# ioscan
H/W Path
============================================================
:
255/0
255/0/0.0
255/0/0.0.0
255/0/0.0.0.0
255/0/0.0.0.1
255/0/0.0.0.2
255/0/0.0.0.3
255/0/0.0.0.4
:
#
When the ETERNUS DX storage systems are connected for the first time, the device file (for exam-
ple, /dev/dsk/c4t0d0) sometimes may not be created.
If this happens, use the "insf" command to create the device file. Specify the hardware path name as
follows, and execute.
# insf -H hw_path_to_device -e
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iSCSI) for HP-UX