Fujitsu ETERNUS4000 400 Manual - Halaman 13

Jelajahi secara online atau unduh pdf Manual untuk Penyimpanan Fujitsu ETERNUS4000 400. Fujitsu ETERNUS4000 400 21 halaman. Disk storage systems (fibre channel) for oracle solaris
Juga untuk Fujitsu ETERNUS4000 400: Manual (28 halaman), Manual Koneksi Server (25 halaman), Manual Koneksi Server (32 halaman), Manual Koneksi (19 halaman)

Fujitsu ETERNUS4000 400 Manual
Chapter 3 Setting Up MPxIO
>
3.2 Solaris 9 OS
3.2.2

Checking the Storage System Status

Use the "format" command to check the path status before multipathing is set up (example out-
put follows).
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c1t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0113ce2e1,0
1. c2t2051000B5D6A0109d0 <FUJITSU-E8000-0000 cyl 6248 alt 2 hd 64 sec 256>
/pci@9,600000/SUNW,qlc@1,1/fp@0,0/ssd@w2051000b5d6a0109,0
2. c3t2050000B5D6A0109d0 <FUJITSU-E8000-0000 cyl 6248 alt 2 hd 64 sec 256>
/pci@9,600000/SUNW,qlc@2,1/fp@0,0/ssd@w2050000b5d6a0109,0
3.2.3

Editing the "/kernel/drv/scsi_vhci.conf" Settings

Edit the "/kernel/drv/scsi_vhci.conf" file.
Procedure
1
2
P3AM-2722-04ENZ0
ETERNUS Disk storage systems Server Connection Guide for Oracle Solaris
Enable MPxIO.
Check that an "mpxio-disable="no";" line exists, enabling MPxIO.
Otherwise, add this line or change its value to "no".
Enable the auto-failback function.
Check that an "auto-failback="enable";" line exists, enabling the auto-failback function.
Otherwise, add this line or change its value to "enable".
"d0" device is connected to c2 and c3 paths.
13
Copyright 2010 FUJITSU LIMITED