Fujitsu ETERNUS8000 2200 Manual - Halaman 24

Jelajahi secara online atau unduh pdf Manual untuk Penyimpanan Fujitsu ETERNUS8000 2200. Fujitsu ETERNUS8000 2200 28 halaman. Disk storage systems (fibre channel) for oracle solaris
Juga untuk Fujitsu ETERNUS8000 2200: Manual (21 halaman), Manual Koneksi Server (25 halaman), Manual Koneksi Server (32 halaman), Manual Koneksi (19 halaman)

Fujitsu ETERNUS8000 2200 Manual
Chapter 9
9.1

Enabling MPxIO

Enable MPxIO.
Check the [mpxio-disable="no"] line in the "/kernel/drv/iscsi.conf" file.
Change the parameter to "no" when "yes" is set.
Example for changing the "/kernel/drv/iscsi.conf" file:
# To globally enable MPxIO on all iscsi ports set:
# mpxio-disable="no";
#
# To globally disable MPxIO on all iscsi ports set:
# mpxio-disable="yes";
#
mpxio-disable="no";
9.2

Reconfiguring and Restarting the Server

Reconfigure and restart the server to effect the new settings.
# touch /reconfigure
# /usr/sbin/shutdown -y -g0 -i6
Use the "format" command to check the MPxIO multipath status after multipathing is set up.
P3AM-4182-03ENZ0
Server Connection Guide (iSCSI) for Oracle Solaris
Setting Up the Multipath Configuration
For the iSCSI LAN (used to transfer data), do not set multipath
configuration with IP Network Multipathing (IPMP).
When configuring the multipath, use MPxIO in the same way as FC-SAN is
used for configuration.
<- Check that no is set.
24
Copyright 2010 FUJITSU LIMITED