Chapter 7 Installing the iSCSI Software Initiator and Setting Up the Server
>
7.2 Setting Up the Server
4
5
6
P3AM-4182-03ENZ0
Server Connection Guide (iSCSI) for Oracle Solaris
Example:
CM0Port0: 192.1.1.120, CM1Port0: 192.1.1.121
# iscsiadm add discovery-address 192.1.1.120
# iscsiadm add discovery-address 192.1.1.121
Enable the connection to the iSCSI Target.
Enable the connection to the ETERNUS Disk storage system that is to be the iSCSI Tar-
get.
# iscsiadm modify discovery -t enable
Create an iSCSI device link.
# devfsadm -i iscsi
Check the ETERNUS Disk storage system.
Check the state of the ETERNUS Disk storage system disks using the "format" command.
Example: ETERNUS2000
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
1. c6t25d0 <FUJITSU-E2000-0000 cyl 510 alt 2 hd 64 sec 256>
/iscsi/[email protected]%3Astorage-system.e2000%3A00001001-cm00002,0
2. c6t26d0 <FUJITSU-E2000-0000 cyl 510 alt 2 hd 64 sec 256>
/iscsi/[email protected]%3Astorage-system.e2000%3A00001001-cm00002,1
3. c6t27d0 <FUJITSU-E2000-0000 cyl 510 alt 2 hd 64 sec 256>
/iscsi/[email protected]%3Astorage-system.e2000%3A00001001-cm10004,0
4. c6t28d0 <FUJITSU-E2000-0000 cyl 510 alt 2 hd 64 sec 256>
/iscsi/[email protected]%3Astorage-system.e2000%3A00001001-cm10004,1
Specify disk (enter its number): Specify disk (enter its number):
18
End of procedure