5.2. Response
Condition
Response
Response that returns the read card data
[track]: Track number (ASCII, '1' to '3')
Description
[data]: Read data string (ASCII)
Condition
Response
Response indicating that there was no data on the track specified with the MCR on command
This response is returned if the specified track does not exist on the card.
[track]: Track number (ASCII, '1' to '3')
Description
["empty"]: The character string "empty" is entered.
Successful Reception Response (When there is data)
Hex
54h
ASCII
T
Track number
Track1: 31h, Track2: 32h, Track3: 33h
SS start code and FC, AS, ES, SS, etc. symbols are not included.
Successful Reception Response (When there is no data)
Hex
54h
ASCII
T
Track number
Hex
ASCII
[track]
3Ah
[track]
:
Multiple bytes
[track]
3Ah
[track]
:
Character string
Track1: 31h, Track2: 32h, Track3: 33h
65h
6Dh
70h
e
m
p
- 32 -
Raster Command Reference
[data]
0Dh
[data]
CR
Delimiter
["empty"]
0Dh
["empty"]
CR
Delimiter
"empty"
74h
79h
t
y
5. MCR Command Specifications
0Ah
LF
0Ah
LF