Indesit Evolution 2005 Panduan Servis - Halaman 11

Jelajahi secara online atau unduh pdf Panduan Servis untuk Oven Indesit Evolution 2005. Indesit Evolution 2005 16 halaman.

Indesit Evolution 2005 Panduan Servis
7. DIFFERENT COMPONENTS:
DESIGNATION
Water tank
Solenoid valve
Door switch
Heat generator
(upside view)
Heating cover
Service Manual
Evolution - 2005
FUNCTION
The tank must be
- Full of water before each
cooking.
- Emptied after each cookingIn
case of too hard water, it's better
to use no calcareous water.
The use of demineralised water
is misadvised.
The solenoid valve supplies the
generator with water
This switch operates as soon as
the door is open/closed.
The generator transforms water
into steam. It is made to receive
back the condensations at the
time of cooking.
Two security thermostats (KX1
and KX2), located underneath the
generator, protect against
overheating (T°C: 210°C).
During all cooking, the heating
cover is supplied in order to avoid
any risk of condensation. It covers
the top of the cavity. Its
temperature is close to 100°C. It
is protected by a thermal fuse.
Edition
2005.03.39
CHARACTERISTICS
Capacity: 1 litre
-
- 220-240 ~
- 2L/min
- 3,7
Door open= Switch is off
Door closed =Switch is on
- 220-240 ~
- 1600 W
- 35
- 220-240 ~
- 35
- 160 W
- Thermal fuse : 120°C
Language
English
G
B
11