Positioning
! ! ! ! ! This unit may be installed and used only in
permanently ventilated rooms according to the
British Standards Codes Of Practice: B.S. 6172/B.S.
5440, Par. 2 and B.S. 6891 Current Editions. The
following requirements must be observed:
a ) a )
a ) a ) The cooker should not be installed in a bed sitting
a )
room with a volume of less than 20m
installed in a room of volume less than 5m
vent of effective area of 110cm
installed in a room of volume between 5m
10m
a supplementary airvent area of 50cm2 is
3
required, if the volume exceeds 11m
required. However, if the room has a door or a
window which opens directly to the outside no air
vent is required even when the volume is between
5m
and 11m
.
3
3
b )
b )
b )During prolonged use of the appliance you may
b )
b )
consider it necessary to open a window to the
outside to improve ventilation.
c ) c )
c ) c ) If there are other fuel burning appliances in the
c )
same room, B.S.5440 Part 2 Current Edition,
should, be consulted to determine the requisite air
vent requirements.
Levelling
If it is necessary to level the
appliance, screw the
adjustable feet into the places
provided on each corner of the
base of the cooker ( see
figure ).
The legs* fit into the slots on
the underside of the base of
the cooker.
Installation of the cooker
The appliance can be installed next to furniture units
which are no taller than the top of the cooker hob.
The wall in direct contact with the back panel of the
cooker must be made of non-flammable material.
During operation the back panel of the cooker could
reach a temperature of 50°C above room
temperature. For proper installation of the cooker,
the following precautions must be taken:
a ) a ) The appliance can be placed in a kitchen, dining
a ) a )
a )
room or bedsit, but not in a bathroom.
b )All furniture around the appliance must be placed
b )
b )
b )
b )
at least 200 mm from the top of the cooker,
should the surface of the appliance be higher than
the worktop of this furniture. Curtains should not
c ) c ) Any hoods must be installed according to the
c ) c )
c )
d )
d )If the cooker is installed beneath a wall cabinet,
d )
d )
d )
. If it is
3
an air
3
is required, if it is
2
e ) e ) The wall in direct contact with the back panel of
e ) e )
e )
and
3
no airvent is
3
f ) f ) f ) f ) f ) The cooker is fitted with a safety chain that must
Fig. A
be placed behind the cooker or less than 200 mm
away from the sides of the appliance.
requirements in the installation manual for the
hoods themselves.
the latter must be situated at a minimum of 420
mm above the hob. The minimum distance
between the worktop and kitchen units made of
combustible material is 700 mm (Fig. A).
the cooker must be made of non-flammable
materials.
be attached to a hook, secured to the wall behind
the appliance.
! Some models can have their gas connection
inverted. It is important to make sure the safety
chain is always situated on the side which
corresponds to the hose holder (Fig. B).
HOOD
600
Min.
mm.
Fig. B

Gas connection

T he cooker should be connected to the gas-supply
by a corgi registered installer. During installation of
this product it is essential to fit an approved gas tap
to isolate the supply from the appliance for the
convenience of any subsequent removal or
servicing. Connection of the appliance to the gas
mains or liquid gas must be carried out according to
the prescribed regulation in force, and only after it is
ascertained that it is adaptable to the type of gas to
be used. If not, follow the instructions indicated in
the paragraph headed "Adaptation to different gas
types". On some models the gas supply can be
connected on the left or on the right, as necessary;
HOT PARTS
to change the
connection, reverse the
position of the hose
holder with that of the
cap and replace the
gasket (supplied with
the appliance). In the
case of connection to
liquid gas, by tank, use
pressure regulators that
conform to the
3
GB