Connecting the drain hose
!
We advise against the use of hose extensions; in case of
absolute need, the extension must have the same diame-
ter as the original hose and must not exceed 150 cm in
length.
Electric connection
Before plugging the appliance into the mains socket, make
sure that:
• the socket is earthed and in compliance with the
applicable law;
• the socket is able to sustain the appliance's
maximum power load indicated in the Technical
details table (see page 5);
• the supply voltage is included within the values i
ndicated on the Technical details table
(see page 5);
• the socket is compatible with the washing
machine's plug. If this is not the case, replace
the socket or the plug.
Your appliance is now supplied with a 13 amp fused plug
it can be plugged into a 13 amp socket for immediate use.
Before using the appliance please read the instructions
below.
WARNING - THIS APPLIANCE MUST BE EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE CARRIED
OUT BY A QUALIFIED ELECTRICIAN.
Connect the drain hose,
without bending it, to a
draining duct or a wall drain
situated between 65 and
100 cm from the floor;
alternatively, place it over
the edge of a basin, sink
or tub, fastening the duct
supplied to the tap (see
figure). The free end of
the hose should not be
underwater.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA approved
fuse to BS 1362 should always be used, and the fuse
cover re-fitted. If the fuse cover is lost, the plug must not
be used until a replacement is obtained.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of the
correct colour as indicated by the coloured marking or the
colour that is embossed in words on the base of the plug.
Replacements can be obtained directly from your nearest
Service Depot.
Removing the plug:
If your appliance has a non-rewireable moulded plug and
you should wish to re-route the mains cable through parti-
tions, units etc., please ensure that either:
the plug is replaced by a fused 13 ampere re-wearable
plug bearing the BSI mark of approval.
or:
the mains cable is wired directly into a 13 amp cable out-
let, controlled by a switch, (in compliance with BS 5733)
which is accessible without moving the appliance.
Disposing of the plug:
Ensure that before disposing of the plug itself, you make
the pins unusable so that it cannot be accidentally inserted
into a socket.
Instructions for connecting cable to an alternative plug:
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Earth
Blue
Neutral
Brown
Live
As the colours of the wires in the lead may not correspond
with the coloured markings identifyng the terminals in your
plug, proceed as follows:
Connect Green & Yellow wire to terminal marked E or
or coloured Green or Green & Yellow.
Connect Brown wire to terminal marked L or coloured
Red.
Connect Blue wire to terminal marked N or coloured Black.
GB