Additional
installation
work for return
air operation
38
Installation steps same
as for exhaust air operation under
points
1—4
Further installation steps:
5.
6.
10.
Slide guide piece (Fig. EO/9) on to chimney cover plate
(Fig. EO/4).
Fix exchaust air hose on guide piece with 125 mm dia. hose
clip.
. Fix chimney equalizer as under exhaust air..
. Unclip the ventilation grille (Fig. EO/8) from the chimney
cover plate and, after pulling off the foil (double adhesive
tape) (Fig. EO/7), slide the chimney cover plate from the `
front on to the fume extractor hood until it engages the hol-
ders on the RH and LH sides (Fig. EO/10).
. Fix chimney cover plate (Fig. EO/2) laterally with 4 2.9 x 6.5
mm sheet metal screws on the chimney retaining plate.
Clip the ventilation grille laterally (on the RH and LH sides)
on the guide piece (Fig. EO/9).
.
Important! Lamination position obliquely downwards!
Unless this has been done as preparation work, 2 KL 600 car-
bon filters (E-No. 610 899 470) (for your own account from our
range of special accessories) must be inserted for return air
operation!