AEG 8609 D Petunjuk Instalasi dan Penggunaan Manual - Halaman 13

Jelajahi secara online atau unduh pdf Petunjuk Instalasi dan Penggunaan Manual untuk Kap Ventilasi AEG 8609 D. AEG 8609 D 24 halaman. Build-in chimney fume extractor hood
Juga untuk AEG 8609 D: Petunjuk Instalasi dan Penggunaan Manual (24 halaman), Panduan Petunjuk Pengoperasian (28 halaman), Buku Petunjuk (28 halaman)

Additional
installation
work for return
air operation
38
Installation steps same
as for exhaust air operation under
points
1—4
Further installation steps:
5.
6.
10.
Slide guide piece (Fig. EO/9) on to chimney cover plate
(Fig. EO/4).
Fix exchaust air hose on guide piece with 125 mm dia. hose
clip.
. Fix chimney equalizer as under exhaust air..
. Unclip the ventilation grille (Fig. EO/8) from the chimney
cover plate and, after pulling off the foil (double adhesive
tape) (Fig. EO/7), slide the chimney cover plate from the `
front on to the fume extractor hood until it engages the hol-
ders on the RH and LH sides (Fig. EO/10).
. Fix chimney cover plate (Fig. EO/2) laterally with 4 2.9 x 6.5
mm sheet metal screws on the chimney retaining plate.
Clip the ventilation grille laterally (on the RH and LH sides)
on the guide piece (Fig. EO/9).
.
Important! Lamination position obliquely downwards!
Unless this has been done as preparation work, 2 KL 600 car-
bon filters (E-No. 610 899 470) (for your own account from our
range of special accessories) must be inserted for return air
operation!
ZMU1
5/90
GB/EU