Kohler 1.1746.005 Instalasi dan Panduan Pengguna - Halaman 8
Jelajahi secara online atau unduh pdf Instalasi dan Panduan Pengguna untuk Perlengkapan Kamar Mandi Kohler 1.1746.005. Kohler 1.1746.005 29 halaman.
Specifications
Plumbing
Minimum Dynamic Pressure
Maximum Dynamic Pressure *
Minimum Static Pressure
Maximum Static Pressure *
Maximum Inlet Temperature
Minimum Inlet Temperature
Inlet Connection
Maximum Water Hardness
Outlet Connection
Electrical
Nominal Power at 230 V ac
Nominal Power at 240 V ac
Recommended MCB Rating
Maximum Supply Cable Size
Recommended RCD Rating
Recommended Isolator Switch
Appliance Sealing Rating
Maximum Ambient Temperature
Minimum Ambient Temperature
Dimensions
Height
Width
Depth
*A drop tight pressure reducing valve should be installed where dynamic or static pressure
exceeds the figure stated in the Specifications.
1494247-W2-A
Thermostatic Variant
Sport 9.0
70 kPa (0.7 bar)
500 kPa (5 bar)
20 kPa (0.2 bar)
1000 kPa (10 bar)
30°C
1/2" BSP Male / 15 mm Compression Fitting
200 ppm CaCO
1/2" BSP Male
Thermostatic Variant
Sport 9.0
8.3 kW
9.0 kW
40 A
16 mm²
30 mA tripping current
45 A double-pole with 3 mm contact separation
IP X4 - Suitable for installation in Zone 1
30°C
358 mm
215 mm
90 mm
8
Sport 9.8
2°C
3
Sport 9.8
9.0 kW
9.8 kW
45 A
2°C