Kohler ARICA K-705232 Panduan Petunjuk Instalasi - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Perlengkapan Kamar Mandi Kohler ARICA K-705232. Kohler ARICA K-705232 12 halaman. Neo-angle shower enclosures

Kohler ARICA K-705232 Panduan Petunjuk Instalasi
J. FINAL ADJUSTMENTS
NOTE: The bottom of the door frame and return
panels should not be more than 1/8" out of
level over the entire width of the door and
panels. Shim if necessary.
Adjust the door frame and return panels for square, level
and plumb.
Make adjustments to the return panels by shifting panels
until level and square.
Use a level to insure that the door is plumb and square.
CAUTION: Risk of product damage. Do not
overtighten adjustment screws.
After the door frame is level, adjust the middle adjustment
screws, being careful not to overtighten as this may cause
the frame to bow.
K. SECURE RETURN PANELS TO WALL
JAMBS
CAUTION: Risk of injury. Wear Safety Glasses.
From inside the shower enclosure, drill through the
internal panel frame and wall jamb extrusions (top and
bottom of each side), using a 1/8" drill bit.
Secure return panels to each wall using four #8-18 x 3/8"
panhead screws.
L. SECURE EXPANDER JAMB BRACKETS
After all adjustments have been made, secure the
expander jamb brackets on each side of the pivot door at
the top of the enclosure.
Insert two #8-18 x 3/4" panhead screws through the
bracket slots and into the corner post screwports and
secure. Repeat for other bracket.
Kohler Co., Kohler, WI U.S.A.
Top View
Expander Jamb
Bracket
7
Wall Jamb
#8-18 x 3/8"
Panhead
Screw
Panel Frame
#8-18 x 3/4"
Panhead
Screw
BC
116896-2-