Kohler BELAY K-23769T-RCP Panduan Petunjuk Instalasi - Halaman 21

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Perlengkapan Kamar Mandi Kohler BELAY K-23769T-RCP. Kohler BELAY K-23769T-RCP 23 halaman.

Kohler BELAY K-23769T-RCP Panduan Petunjuk Instalasi
Whirlpool System and in-line Heater
Symptoms
1. Whirlpool does not
start or stop.
2. Pump motor starts, but
not all jets are
functioning.
3. in-line heater does not
operate.
1.
2.
3.
1397340-T01-A
Probable Causes
A. No power to the pump
motor.
B. Air actuator tubing is loose
or disconnected.
C. Air actuator tubing is
pinched or kinked.
D. Air system button assembly
is damaged.
E. Air system button assembly
has grease or debris in the
bleed area.
F. Air actuator tubing is
damaged.
G. Pump motor does not work.
A. A jet is closed.
B. Jets are not installed
correctly.
C. Jets are blocked.
A. No power to the in-line
heater.
B. Water temperature exceeds
°F
°C
104
(40
).
C. in-line heater does not work.
A.
B.
C.
D.
E.
F.
G.
A.
B.
A.
B.
/
Recommended Action
A. Set or reset the
wiring.
B. Check that the air actuator tubing is connected
to the air switch actuator, and to the air switch
button. Reconnect if needed.
C. Adjust the air actuator tubing to clear the
pinched or kinked area.
D. Replace the air system button assembly.
E. Disassemble the air system button assembly,
and wipe away any excess grease or debris.
Reassemble the air system button assembly,
and test operation.
F. Replace the air actuator tubing.
G. Replace the pump motor.
A. Rotate the jet trim ring counterclockwise to
open.
B. Reinstall the jet.
C. Remove blockage.
A. Set or reset the
wiring.
B. Allow water to cool, and the heater will re-
engage.
C. Replace the in-line heater.
A.
RCD
B.
C.
D.
E.
F.
G.
A.
B.
A.
RCD
B.
-21-
RCD
. Check and repair the
RCD
. Check and repair the