Problem
The drying cycle
is too short.
Drying cycle too
5)
long
1) Follow the programme description — see the PROGRAMMES chapter .
2) See the
CARE AND CLEANING chapter.
3) Only dryers with the Dryness Level option.
4) See the HINTS AND TIPS chapter .
5) Note: After a maximum of 5 hours the drying cycle ends automatically.
11.3 Possible causes of
unsatisfactory drying results:
• The filter is clogged. Clogged filter
makes drying inefficient.
• The airflow slots are clogged.
• The humidity sensor is dirty.
• The drum is dirty.

12. TECHNICAL DATA

Height x Width x Depth
Max. depth with the appliance door open
Max. width with the appliance door open
Adjustable height
Drum volume
Maximum load volume
Possible cause
The load size is small.
The laundry is too dry.
The filter is clogged.
The load is too large.
The laundry was not spun suffi‐
ciently.
Too low or too high room tempera‐
ture - this is not the appliance mal‐
function.
Select a time programme. The
time value must be related to the
load. To dry one item or a small
amount of laundry we recommend
short drying times.
Select an appropriate time pro‐
gramme or a higher dryness level
extra dry )
(e.g.
Clean the filter.
Do not exceed the maximum load
size.
Spin the laundry well in the wash‐
ing machine.
Ensure a room temperature higher
than +5°C and lower than +35°C.
Optimal room temperature to ach‐
ieve best drying results is between
18°-25°C.
• Inadequate default dryness level
settings. See chapter
default dryness level
• Room temperature is too low or too
high. Optimal room temperature is
between 18°-25°C.
850 x 596 x 638 mm (maximal 663 mm)
1108 mm
958 mm
850 mm (+ 15 mm - feet regulation)
118 l
8,0 kg
Remedy
Adjustment of