Kohler STERLING 76301100 Panduan Pemilik Rumah - Halaman 7
Jelajahi secara online atau unduh pdf Panduan Pemilik Rumah untuk Perlengkapan Kamar Mandi Kohler STERLING 76301100. Kohler STERLING 76301100 29 halaman. Whirlpool bath
Troubleshooting (cont.)
Symptoms
1.
Whirlpool does not
start/stop.
2.
Motor starts, all jets are
not functioning.
3.
Whirlpool stops by itself.
4.
Whirlpool is noisy.
Sterling
Probable Causes
A. No power to the pump motor.
B. Air actuator does not work.
C. Pump motor does not work.
A. Jet is closed.
B. Jets are blocked.
A. GFCI trips.
B. Suction blocked.
C. Jets are blocked.
D. The motor has overheated and
protection device has activated.
A. The pump banding straps that
hold the pump to the bath have
not been cut.
7
Recommended Action
A. Set or Reset the GFCI breaker.
Check the wiring. If the problem
persists, refer to your installer or
dealer.
B. Check the air tube connections.
Replace the air actuator. Refer to
your installer or dealer.
C. Replace the pump motor. Refer to
your installer or dealer.
A. Rotate the jet trim ring
counterclockwise to open.
B. Remove the blockage.
A. Identify the source of fault and
correct it. If the problem persists,
refer to your installer or dealer.
B. Remove the obstruction.
C. Remove the blockage.
D. Check for blockage at the motor
vents. Remove blockage and allow
motor to cool. Check for suction
blockage. Remove the blockage and
allow motor to cool. Check for jet
blockage. Remove the blockage and
allow motor to cool.
A. Cut the pump banding straps with
tin snips.
1016905-5-L