Kohler K-1164 Panduan Instalasi - Halaman 14

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Bak mandi Kohler K-1164. Kohler K-1164 44 halaman. Bath with airjets
Juga untuk Kohler K-1164: Panduan Pemilik Rumah (32 halaman), Panduan Pemilik Rumah (29 halaman), Panduan Instalasi (48 halaman), Panduan Pemilik Rumah (36 halaman), Manual Pengasahan Awal (Roughing-In) (4 halaman), Panduan Instalasi dan Perawatan (21 halaman), Panduan Pemilik Rumah (29 halaman)

Kohler K-1164 Panduan Instalasi
Troubleshooting Procedure (cont.)
Symptoms
3. Whirlpool stops automatically
before 18 minutes.
4. Pump does not prime. (Models
with support blocks only.)
5. Noisy operation.
6. Heater does not operate. ("H"
models only)
1010914-2-D
Probable Causes
B. Jet not installed correctly.
C. Jets are blocked.
A. The GFCI or ELCB trips.
B. Suction blocked.
C. Jets are blocked.
D. Motor overheated and
protection device activated.
A. Pump shimmed too high.
A. Pump banding straps have not
been cut. (Models with support
blocks only.)
B. Jet O-ring dislodged.
A. No power to heater.
B. Water temperature exceeds
104° F (40° C).
C. Heater does not work.
14
Recommended Action
B. Reinstall jet; check for O-ring
damage.
C. Remove blockage.
A. Identify source of fault, and
correct.
B. Remove obstruction.
C. Remove blockage.
D. Check for blockage at motor
vents. Remove blockage and
allow motor to cool.
Check for suction blockage.
Remove blockage and allow
motor to cool.
Check for jet blockage. Remove
blockage and allow motor to
cool.
A. Lower pump support bracket.
A. Cut pump banding straps with
tin snips.
B. Remove jet, replace and
lubricate O-ring, and reinstall
jet.
A. Reset the GFCI or ELCB.
B. Allow water to cool and heater
will reengage.
C. Replace heater.
Kohler Co.