3.2 1.4BEOR Features

The 1.4BEOR is equipped with the features as shown in
Figure 3-1.
3
1. Main electric power supply fuses (min. 200 amp for 12-volt
models)
2. Diesel on/off valve
3. Fixed protection cases
Figure 3-1 Features
WARNING
Carbon monoxide.
Can
cause
fainting, or death.
The
exhaust
leakproof and routinely inspected.
Generator set operation. Carbon monoxide can cause
severe nausea, fainting, or death. Carbon monoxide is an
odorless, colorless, tasteless, nonirritating gas that can cause
death if inhaled for even a short time. Avoid breathing exhaust
fumes when working on or near the generator set. Never
operate the generator set inside a building unless the exhaust
gas is piped safely outside. Never operate the generator set
where exhaust gas could accumulate and seep back inside a
potentially occupied building or vehicle. Do not obstruct the
exhaust outlet when parking your vehicle. The exhaust gases
must discharge freely to prevent carbon monoxide from
deflecting into the vehicle.
16
Section 3 Operation and Use
1
2
tp6576
severe
nausea,
system
must
be
Carbon monoxide symptoms. Carbon monoxide can
cause severe nausea, fainting, or death. Carbon monoxide
is a poisonous gas present in exhaust gases.
monoxide is an odorless, colorless, tasteless, nonirritating gas
that can cause death if inhaled for even a short time. Carbon
monoxide poisoning symptoms include but are not limited to
the following:
D Light-headedness, dizziness
D Physical fatigue, weakness in
joints and muscles
D Sleepiness, mental fatigue,
inability to concentrate
or speak clearly, blurred vision
D Stomachache, vomiting, nausea
If experiencing any of these symptoms and carbon monoxide
poisoning is possible, seek fresh air immediately and remain
active. Do not sit, lie down, or fall asleep. Alert others to the
possibility of carbon monoxide poisoning. Seek medical
attention if the condition of affected persons does not improve
within minutes of breathing fresh air.

3.3 Operating Modes

The generator can be operated by controls located on
the remote control unit, according to the settings and
procedures described in the paragraphs under
Section 3.4, Operating Instructions.

3.4 Operating Instructions

3.4.1

Alarm Horn

An alarm horn sounds whenever the engine starts up.
The alarm horn is automatically controlled by the ECU.
It is activated during the last 5 seconds of glow plug
preheating and is turned off at the end of the glow plug
preheating time.
1. Alarm horn