Kohler 1.4BEOR-12V Operasi - Halaman 31

Jelajahi secara online atau unduh pdf Operasi untuk Generator Portabel Kohler 1.4BEOR-12V. Kohler 1.4BEOR-12V 44 halaman. Heavy duty truck mobile generator sets

WARNING
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
on the
Remove the negative (--) lead first
when disconnecting the battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
WARNING
Fire.
Can cause severe injury or death.
Do not smoke or permit flames or
sparks near fuels or the fuel system.
TP-6687
9/10
generator set.

Section 6 Scheduled Maintenance

Disabling the generator set.
cause severe injury or death.
generator set or connected equipment, disable the generator
set as follows: (1) Move the generator set master switch to the
OFF position. (2) Disconnect the power to the battery charger.
(3) Remove the battery cables, negative (--) lead first.
Reconnect the negative (--) lead last when reconnecting the
battery. Follow these precautions to prevent starting of the
generator set by an automatic transfer switch, remote
start/stop switch, or engine start command from a remote
computer.
Operations concerning mechanical components that
must be performed every 500 hours:
D
Operations to adjust the rocker arm blocks.
D
Calibration and cleaning injector.
D
Replacement of the compressor drive belt.
D
Maintenance of the cooling fins.
Accidental starting can
Before working on the
Section 6 Scheduled Maintenance
31