13
TROUBLESHOOTING
Problem
Smoke or dust
escaping from the
filter or around
the filter frame
Drop in filter
efficiency
17
Probable cause
Filter envelope not
installed properly
Leak in filter envelope
Damaged seal
High level of humidity
within the collector
Air volume too
low or too high
Filter envelope not
suited for dust to be
filtered
Filtered air tempe-
rature is higher than
normal
Static electricity build
up in dust collector
Multiple pocket type dust collector
Solution
Tighten fasteners on filter frame to ensure proper seal.
Repair or replace filter envelope.
Repair or replace seal.
Check humidity level or relative humidity within the col-
lector. A slightly higher humidity level may be corrected
by closing some gates and by shaking the filter. If the
humidity level is too high, take necessary measures to
dry the the air before it enters the collector.
Check for speed and motor rotation and the position of
gates. Make necessary adjustments to obtain original
specifications.
Replace filter envelope with a filtration system suited for
the dust to be filtered.
Check temperature of air to be filtered. Bring necessary
adjustments to obtain satisfactory temperature.
Check for appropriate grounding wires of collector, com-
ponents and ducting system. Increase relative humidity
of air to be filtered if lower than 50% R.H. until the dust
to be filtered is affected.