Load detergent duration
This item of programming menu (par 3.10-3.11-3.12 DET4 manual and 3.13), defines the time of dosing in the first
phase of loading the dishwasher. During this period are executed one or more periods of dosing cycle (Section
3.2). The dosage of detergent in the loading phase is independent of the conductivity, when it is working with the
probe.
3.5
Duration of detergent recovery
This item of programming menu (par 3.11 and 3:13 DET4 manual) defines the dosing time during recoveries, that
means on the activation of the signal RINSE. In operation without conductivity probe, during this period are
executed one or more periods of dosing cycle (Section 3.2). This item is available only if the operation is timed.
3.6
Det Speed
This item of programming menu (par 3.11 and 3:13 DET4 manual), defines a percentage change of 15%-100% of
EVTON and EVTOFF of cycle period on recoveries (Section 3.2 DURATION RESET).
EVTON = DET speed * EVTON_PROG
EVTOFF = ((100 - DET speed) * EVTON_PROG/100) + EVTOFF_PROG
3.7
Dosing activation
This item of programming menu (par 3.10 and 3:12 DET4 manual, work with conductivity probe), enables or
disables the dosage of detergent on the signal wash (wash pump). If you leave this item at the default value of
"REPORTED" when the wash pump is active it will follow the dosing of chemicals as reported in Tab. 1. If you
program this menu item to "Automatic", the system always executes the dosing as reported in TABLE 1. We
recommend that you leave this item in the "REPORTED" (connecting the signal from the wash pump entrance
WASH; DET4 manual par 2.5.5).
The following table summarizes the dosage of the detergent when the probe is used:
CONDUCTIVITY
C< 65% SETPOINT
65%SETPOINT <C <90% SETPOINT
90%SETPOINT <C <110% SETPOINT
NOTE: THE CONDUCTIVITY DOES NOT
HAVE REACHED THE 110% OF THE SET
POINT
90%SETPOINT <C <110% SETPOINT
NOTE: THE CONDUCTIVITY ABOVE HAS
REACHED THE 110% OF THE SET POINT
C> 110 % S
CONDUCTIVITY
ETPOINT
Note: EVTON_PROG and EVTOFF_PROG are the values programmed in the Setup Menu
ADSP7000645
EVTON
EVTON_PROG
EVTON = 80%
EVTOFF = EVTOFF_PROG+EVTOFF_PROG -
EVTON_PROG
(80% EVTON_PROG).
EVTON = 80%
EVTOFF = EVTOFF_PROG+EVTOFF_PROG -
EVTON_PROG
(80% EVTON_PROG).
EVTON = 0
EVTOFF = EVTOFF_PROG+EVTOFF_PROG
SEC
EVTON = 0
EVTOFF = EVTOFF_PROG+EVTOFF_PROG
Rev. 1.0
EVTOFF
EVTOFF_PROG
11/12