Aqua Control SELECT Series 2 Buku Petunjuk - Halaman 8

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Peralatan Rumput dan Taman Aqua Control SELECT Series 2. Aqua Control SELECT Series 2 19 halaman. Display aerator

CONNECTOR CAPS
WARNING: Do not use grease on connectors. No tools are required for tightening.
3-WIRE PUMP CABLE
MOTOR LEAD CONNECTOR
FROM CONTROL PANEL
2 Wire with Ground
Motor Lead Connector
& Light Set Connector
Neutral
Hot
Ground
8
CONNECTORS
CONNECTOR CAPS
Blue connector caps are used to protect the connectors during handling and to keep them dry if submerged
while unconnected to mating connectors.
CONNECTOR IDENTIFICATION
4-WIRE PUMP CABLE
MOTOR LEAD CONNECTOR
FROM CONTROL PANEL
WIRE IDENTIFICATION
2 Wire with Ground
Pump Cable Connector
& Light Cable Connector
Ground
Neutral
Hot
Aqua Control, Inc. 60 Hz. Select Series 2 Instruction Manual
FROM CONTROL PANEL
3 Wire with Ground
Motor Lead Connector
Red
Yellow
Ground
Black
LIGHT CABLE
FROM LIGHTS
3 Wire with Ground
Pump Cable Connector
Ground
Black
Red
Yellow