MAKE-UP AIR. Adequate make-up air (910 CFM) (26 m
exhausted by dryers on all types of installations. Provide a minimum of 1.25 sq. ft.
2
(.12 m
) make-up air opening to the outside of each dryer. This is a net requirement of effective
area. Screens, grills or louvers which will restrict the flow of air must be considered. Consult the
supplier to determine the free area equivalent for the grill being used.
The source of make-up air should be located sufficiently away from the dryers to allow an even
air flow to the air intakes of all dryers. Multiple openings should be provided.
NOTE: The following considerations must be observed for gas dryer installations where dry
cleaners are installed. The sources of all make-up air and room ventilation air movement to all
dryers must be located away from any dry cleaners. This is necessary so that solvent vapors will
not be drawn into the dryer inlet ducts. Dry cleaner solvent vapors will decompose in contact
with open flame such as the gas flame present in clothes dryers. The decomposition products are
highly corrosive and will cause damage to the dryer(s) ducts and clothes loads.
The operation of this appliance may affect the operation of other types of gas appliances which
take their air for safe combustion from the same room. All other gas appliances should be tested
with the Dexter dryer in operation and all the windows and doors closed. If in doubt consult the
appliance manufacturer(s).
4. ELECTRICAL REQUIREMENTS: 230V~ 50Hz 1.2kW
The electrical power requirements necessary to operate the unit satisfactorily are listed on the
serial plate located on the back panel of each dryer. The electrical connection should be made to
the terminal board in the control box on the rear of the unit using a wire size adequate to handle
the amperage and voltage listed on the serial plate. It is absolutely necessary that the dryer be
grounded to a known (earth) ground.
The installation must meet the National Electrical Requirements of the country of installation.
Individual 15 A circuit breakers for each dryer are required. The installer must provide a
disconnect switch which will interrupt both lines. It may be a local or national requirement to
provide an electrical interruption switch visible and accessible from the room in which the dryer is
installed. The wiring diagram is located on the belt guard on the back of the dryer.
5. GAS REQUIREMENTS. The complete gas requirements necessary to operate the dryer
satisfactorily are listed on the serial plates located on the back panel of the dryer.
This appliance has been certified for use in the following countries:
. This appliance is factory adjusted for G20 gas supply at either 20 or 50 mbar
CH, DK and GR
supply pressure.
3
/Min.) must be supplied to replace air
-6-
GB, IE, BE, FR, DE, NL, ES,