INPUT, OUTPUT AND CONTROL SECTION
1. AUDIO INPUT ("Balanced audio Input") with Mic/Line input selector.
Input compatible with balanced XLR cables. Used for the input connection of the audio signal coming from the
mixer (selector set to "Line") or from a microphone (selector set to "Mic").
2. MAIN PRESET
Rotary switches to set the presets based on application and context of use.
3. AUDIO OUTPUT ("Output/Link")
Connector compatible with balanced cables with XLR connectors. It is used for the output connection, both
directly and with the link to another monitor (Link).
4. INPUT SENSITIVITY
It allows adjusting the input sensitivity.
Before starting monitor and system confi guration, set at 0 dB.
5. STATUS LEDs ("Status")
LEDs relating to module operation.
Limiter: lights up in case of activation, and possibly provides a warning signal - to be checked - with cyclic fl ashing.
ON/Signal: it lights up discontinuously/continuously signalling the presence of an input signal.