Dexter Laundry HIGH SPEED 25LB WASHER Petunjuk Pemasangan & Pengoperasian - Halaman 4
Jelajahi secara online atau unduh pdf Petunjuk Pemasangan & Pengoperasian untuk Mesin cuci Dexter Laundry HIGH SPEED 25LB WASHER. Dexter Laundry HIGH SPEED 25LB WASHER 14 halaman. High extract washer 25 lb (11.4 kg) capacity stackable on-premise laundry computer control
PLUMBING
Water supply hoses are furnished with each machine. Separate hot and cold water lines must be
provided, maintaining 30 P.S.I . (207 kPa) to 120 P.S.I. (818 kPa) water flow pressure. A 140F
(60C) degree hot water supply is recommended for best washing results.
DRAIN
The drain outlet tube at the rear of the machine is 3 inches (76 mm) in diameter. A flexible hose
material (Pt. #9242-417-003) is available to extend this draining system. Any drain hose used must
be lower than the drain valve to assure proper draining.
ELECTRICAL 208-240V/1PH/60HZ OR 208-240/3PH/60HZ
SHUT OFF POWER AND WATER BEFORE OPENING ANY SERVICE PANELS.
This Dexter washing machine is intended to be a permanently installed appliance. No power cord is
provided. The machine should be connected to an individual branch circuit not shared by lighting or
other equipment. Where required, a means for disconnection with a contact separation distance of at
least 3mm must be provided. The connection should be sheathed in liquid-tight flexible conduit, or
equivalent, with conductors of the proper size and insulation.
TO MAKE ELECTRICAL CONNECTIONS: Disconnect all power to the washer. Remove screw and
lift out the cover located in the upper left corner of the machine (as viewed from the back).
If power is 208-240-3PH-60Hz, connect L1, L2, L3 and ground. If there is a high leg it must be
connected to L3.
If power is 208-240-1PH-60Hz, connect L1, L2 and Ground.
NOTE: It is important that the grounding screw next to the power terminal block TB-1 be
connected to a good external ground.
FUSING REQUIREMENTS:
SINGLE- or THREE -PHASE POWER - 20 AMP TIME-DELAY (DUAL ELEMENT) FUSE
(or equivalent circuit breaker)
CONTROLS TRANSFORMER
The controls transformer is mounted at the back of the control trough and has two voltage range
settings. One terminal is provided for the range of 208 to 220 volts and the other is for the range of
221 to 240 volts. Make sure the transformer is wired to match the intended supply voltage.
INJECTION SOURCE DETAILS
WARNING